SCSI Bus Signal Converters
6.4 Terminating SCSI Buses
Figure 6–2 End-Bus DWZZA Bus Terminators
SINGLE-ENDED
SCSI-2 TERMINATION
DIFFERENTIAL
TERMINATOR
RESISTOR SIPS
68-PIN
CONNECTOR
J2
CXO-3836A-MC
5. Terminate the SCSI–P cable by installing the five resistor single-inline-
packages (SIPs).
6. Replace the SBB cover and bezel or replace the desktop cover.
7. Label the SBB bezel or the desktop cover with the status of both the
differential terminator and the single-ended terminator as either "IN" or
"OUT."
8. Install the SBB, in the shelf, connect the SCSI cable, and apply power to the
shelf.
9. Observe the system to determine if the SCSI bus and devices are functioning
properly.